High Frequency Mobile C-arm System

High Frequency Mobile C-arm System
Product Detailed
1.High Frequency Mobile C-arm System 2. Max rated capacity:5kw 3.Impoted CCD 4.Large focus: 1.5 5.Voltage:40-110kv

High Frequency Mobile C-arm System

Specifications

Fluoroscopic Capacity

Max rated capacity : Tube Current 4mA, Tube Voltage 120kV

Automatic Fluoroscopy : Tube Voltage:40kV~120kV adjust

automatically

Tube Current : 0.3mA~4mA set manually

Manual Fluoroscopy : Continuous Tube Voltage:40kV~120kV

Continuous Tube Current : 0.3mA~4mA

Pulse Fluoroscopy : Continuous Tube Voltage 40kV~120kV

Continuous Tube Current 4.1mA~8mA

Photography Capacity

Max rated capacity : 5 KW

Tube Voltage and Cur-

rent Combination : 40kV~49kV 1 ~180 mAs

50kV~59kV 1 ~140 mAs

60kV~69kV 1 ~125 mAs

70kV~79kV 1 ~110 mAs

80kV~89kV 1 ~100 mAs

90kV~99kV 1 ~80 mAs

100kV~109kV 1 ~63 mAs

110kV~120kV 1 ~50 mAs

Plate holder Size : 200mm×250mm(8″×10″)or

250mm×300mm(10″×12″)

X-ray Tube

X-ray Tube Special for High Frequency

Fixed anode Dual-focus: large focus: 1.5, small focus: 0.3

Inverter Frequency : 40KHz

Thermal capacity : 35KJ (47KHU)

Video System

Image Intensifier : Image Intensifier made by TOSHIBA (9″)

CCD Vidicon : Ultra low-light CCD camera imported from

Japan

Monitor : Horizontal 1000 lines and vertical

800 lines, Bandwidth : 12.5MHz,

Image/sec : 75

CCU(central control) : Recursive Filter: K=8,8 images storage,

image upright, image overturn,positive &

negative image LIH(last image freeze, and

OSD(monitor display)

Structure:

Directive wheel : ±90°revolution,can freely change the moving

direction of the unit .

Ascending & Descending

Range of Pillar : ≥400mm

C-arm : Forward and Backward Movement: 200mm

Revolution around Horizontal Axis: ±180°

Revolution around Vertical Axis : ±15°

Slip on orbit: 120°(+90°~ -30°)

Packing Details : 2440mm×1100mm×1420mm

N.W. 300kgs G.W.400kgs

Features

1,With a compact appearance, and easy to operate;

2,Clinical Video system with high performance,8 images storage

volume, and two 14''high-resolution monitors;

3,Automatically track fluoroscopy to make the image brightness and

clearness optimum;

4,Automatically store the last image of fluoroscopy to advantage

diagnosis;

5,With a high-quality knockdown X-ray generator to reduce radiation

High Frequency Mobile C-arm System