DR500U High-Frequency 500mA Digital Imaging System
DR500U High-Frequency 500mA Digital Imaging System
Technical parameters
Items | Technical parameters | |
Power condition | Power | a.c380V±38V |
Current | 50Hz | |
Inner resistance | ≤0.5Ω | |
Max tube voltage | 150kV | |
Max tube current | 500mA | |
High voltage working frequency | 30kHz | |
Photography | Tube voltage | 40~150kV,stepped 1kV |
Tube current | Small focus100,200mAbig focus200,320,400,500mA | |
Powder time plot | 0.5~500mAs,total 60 stpes | |
High frequency and high voltage generator(including console) | Max output powder | 50kW |
Rectifier | One-way full-wave bridge rectifier | |
X-ray tube | Focus | Small 0.6mm,big 1.2mm |
Power | Small focus 19kW,big focus 50kW | |
Anode heat capacity | 150kHU | |
Anode speed | 2800r/min | |
UC arm | Focus to ground distance | 465~1700mm |
SID | 1000~1800mm | |
Arm rotary rang | -30°~ +120° | |
Detector rotary rang | -30°~ +30° | |
Detector | Spatial resolution | 4.0 Lp/mm |
Imaging time | 5s | |
Preview time | 4s | |
Effective image size | 430mm×430mm | |
Unit size | 140micron | |
Pixel | 3k×3k,900 ten thousand | |
Out put gray scale | 14bit | |
Beam limited device | Optical positioning, manual multi-leaf type | |
Software function | Management of data security | Products to cope with various operations involved in patient data management to provide authorization, and only authorized person can operate accordingly |
Case management | a) case management features: including patient information, inspection information and image management; b) DICOM3.0 standard Worklist query service, customizable HIS / PACS clinical data query and download. | |
Imaging collect | a) has a detector calibration function can be directly from the software calibration detector; b) digital photography functions, can be configured to positive and negative film image acquisition; c) real-time automatic window width and window level adjustment; d) real-time automatic ROI cutting; e) Real-time edge enhancement; f) according to different selection mirrored and rotated position; g) to display patient information, check information, equipment information, image information. | |
Imaging treatment | a) window width and window level, and Gamma adjustment, multi-LUT curve adjustment; b) positive and negative film conversion, image scaling, translation, mirroring, rotating, magnifying glass display; c) choose the original region of interest shows, full-screen display, histogram display, window width and window level adjustments; d) image enhancement, noise reduction can be set different according to different parts of the program to enhance and strengthen the degree adjustable; e) image annotation features, including draw straight lines, rectangles, polygons, arrows and text; f) Real-time alert system can store the number of images | |
Imaging Output | a) DICOM3.0 standard laser camera output can be easily configured to select the program (film size, layout) printing; b) DICOM send SCU, support for sending images to any follow DICOM3.0 standard PACS and workstations; c) the image backup, the backup image to CD / DVD. |
DR500U High-Frequency 500mA Digital Imaging System